Maintenance of Series H Right Angle Gearboxes
A. It is the first time that New gearbox has bee used, after running for 300 hours you must renew the gear oil. After shutdown the oil which is hot is discharged at once. After during running each 2,000 hrs. of running or amounted to 6 months of natural time taking first achievement of them the gear oil should be renewed usually.
B. All bolts are inspected and screwed down regularly.
C. After the gearbox working 20,000 hrs. the clearance and wear conditions should be inspected for two end bearings of the horizontal shaft and upper bearings of the vertical shaft, and at exceeding limit should be renewed.
Attention: new bearing ought to be heated in lubricant first, before is set to shaft. The down
bearing of the vertical shaft isn’t liable to dismount owing to its down end there is a pump pulley whose shrink range is much, so the working life of the bearing has been designed to be very long. Under conditions that the gearbox uses and lubricates normally its working life is generally from 70,000 to 100,000 hours.
China Right Angle Gearboxes manufacturer provides Right Angle Gearboxes with affordable prices and stable performance. For more information, please contact 008613974960765.
Vertical PWDDFL Multi-suction Sewage Sump Pump
VS6 Vertically Suspended Radial Canned Turbine pump
Vertical turbine Industrial Can-Type Pumps
Semi-submersible Vertical Industrial Turbine Pumps
Semi-submersible Canned Vertical Turbine pump
Short-Set Vertical Turbine pumps
Vertical Cryogenic Process Canned vertical turbine pump
Vertical Canned Process Semi-submersible turbine pump
Canned Vertical Turbine Generators Pump
Vertical long shaft turbine pumps
Semi-submersible Mixed-Flow Vertical Turbine Pumps
Vertical Semi-submersible chemical sump pump
TEL:073184800558 073184810558
Cell Phone:008618507312158 008613974960765
E-mail:sale@ljpump.net
Address:Xiangyin Industrial Park, Jinlong Town, Xiangyin County, Hunan Province, China